TESLA Fault

BMS-F077

BMS_f077_SW_Charger_Regulation

Also written as BMS_F077 / BMS F077 / BMS_f077_SW_Charger_Regulation / bms_f077_sw_charger_regulation

System
BMS
Battery Management System
Type
Fault
Category
Battery
Severity
Fault (Critical)

Why does the exact Tesla alert ID matter?

Record the exact alert ID, including underscores, suffixes, and companion alerts. Tesla alerts that look similar can point to different modules, timestamps, and service procedures.

What does BMS-F077 mean?

Tesla fault code in the Battery Management System (BMS) module. The Battery Management System (BMS) has stopped charging due to the maxBrickV in the high voltage (HV) battery reaching the maxBrickVTarget value.

Original Description

The Battery Management System (BMS) has stopped charging due to the maxBrickV in the high voltage (HV) battery reaching the maxBrickVTarget value.

Affected Tesla Models

Model SModel XModel 3Model YCybertruck

What You May Notice

  • Red warning light on dashboard: The Battery Management System (BMS) has stopped charging due to the maxBrickV in the high voltage (HV) battery reaching
  • Vehicle may refuse to drive or charge until the fault is cleared
  • Sudden power reduction or shutdown may occur while driving

How to Diagnose and Resolve

  1. 1 Stop driving immediately and move to a safe location
  2. 2 Do not attempt to charge the vehicle โ€” active fault: "The Battery Management System (BMS) has stopped charging due"
  3. 3 Call Tesla Roadside Assistance (+1-877-798-3752) for a flatbed tow
  4. 4 At the Service Center, Tesla technicians will inspect the HV battery pack and BMS firmware

Severity Notes

BMS-F077 is classified as a Fault, indicating a critical issue in the Battery Management System system. Do not continue driving and contact Tesla Service immediately.

Other BMS Codes

View all BMS codes โ†’