TESLA HVAC

Tesla TAS2 Alert Codes

Thermal Architecture System v2 reference page with 94 Tesla alert codes, 89 detailed descriptions, severity counts, and diagnostic context.

0
Critical
0
Warning
94
Caution
0
Info

What the TAS2 system covers

Thermal Architecture System v2 alerts belong to Tesla's proprietary diagnostic alert system and are grouped under the hvac category.

Read all active alerts together instead of diagnosing a single code in isolation.
Check recent service, firmware updates, and low-voltage battery condition.
Use Tesla Service or a qualified EV technician for safety-critical systems.

Alert type breakdown

Alert 94

Tesla TAS2 code list

Rows with a linked code have a dedicated detail page.

Download CSV
Code Severity Type Description
TAS2_a001
TAS2_a001_WatchdogReset
Caution Alert
TAS2_a001 - Watchdog Reset

Tesla alert code in the Thermal Architecture System v2 (TAS2) module related to watchdog reset.

TAS2_a015
TAS2_a015_NVMMAlert
Caution Alert
TAS2_a015 - NVMM Alert

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert indicates there is a mismatch, new record, or a missing record in the non-volatile memory on the Tesla Air Suspension Controller (TAS) board. Certain parameters, such as ride height calibration offsets, are stored in the Non-Volatile Random Access Memory (NVRAM). This alert does not affect vehicle operation.

TAS2_a025
TAS2_a025_CrashEvent
Caution Alert
TAS2_a025 - Crash Event

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. Tesla Air Suspension (TAS) has received a message from the Gateway indicating that the vehicle experienced a crash event (SDM3 message for Model S and the RCM_collision message for Model X). TAS enters Limp Home Mode 40 to prevent any further leveling. For more information on Limp Home Mode 40, see Article #26133.

TAS2_a030
TAS2_a030_PWMerrorFL
Caution Alert
TAS2_a030 - PW Merror FL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every repeated fault and triggers the fault at a threshold of 50. The weighted counter decrements by 1 for every valid reading and clears the fault when it reaches 0. TAS2_a030_PWMerrorFL will trigger if any of the following faults are set: PWM_OVER_MAX_DUTY Set:The height sensor PWM signal has had a duty cycle greater than 87.5% for 50ms.Clear:The height sensor PWM signal has had a duty cycle less than 87.5% for 500ms. PWM_UNDER_MIN_DUTY Set: The height sensor PWM signal has had a duty cycle less than 12.5% for 50ms.Clear:The height sensor PWM signal has had a duty cycle greater than 12.5% for 500ms. PWM_OVER_MAX_PERIOD Set: The height sensor PWM signal has had a period greater than 0.00131579 seconds for 50ms.Clear:The height sensor PWM signal has had a period less than 0.00131579 seconds for 500ms. PWM_UNDER_MIN_PERIOD Set: The height sensor PWM signal has had a period less than 0.00119048 seconds for 50ms.Clear:The height sensor PWM signal has had a period greater than 0.00119048 seconds for 500ms. PWM_OVER_MAX_DELTA_DUTY (cannot be set if transitioning to/from 0 or 100% duty cycle) Set: The height sensor PWM duty cycle has changed by more than 33% (3.3 * 10ms alert period) since its previous cycle for 50ms.Clear: The height sensor PWM duty cycle has changed by less than 33% (3.3 * 10ms alert period) since its previous cycle for 500ms.

TAS2_a031
TAS2_a031_PWMerrorFR
Caution Alert
TAS2_a031 - PW Merror FR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every repeated fault and triggers the fault at a threshold of 50. The weighted counter decrements by 1 for every valid reading and clears the fault when it reaches 0. TAS2_a031_PWMerrorFR will trigger if any of the following faults are set: PWM_OVER_MAX_DUTY -Set:The height sensor PWM signal has had a duty cycle greater than 87.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle less than 87.5% for 500ms. PWM_UNDER_MIN_DUTY -Set: The height sensor PWM signal has had a duty cycle less than 12.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle greater than 12.5% for 500ms. PWM_OVER_MAX_PERIOD -Set: The height sensor PWM signal has had a period greater than 0.00131579 seconds for 50ms. -Clear:The height sensor PWM signal has had a period less than 0.00131579 seconds for 500ms. PWM_UNDER_MIN_PERIOD -Set: The height sensor PWM signal has had a period less than 0.00119048 seconds for 50ms. -Clear:The height sensor PWM signal has had a period greater than 0.00119048 seconds for 500ms. PWM_OVER_MAX_DELTA_DUTY (cannot be set if transitioning to/from 0 or 100% duty cycle) -Set: The height sensor PWM duty cycle has changed by more than 33% (3.3 * 10ms alert period) since its previous cycle for 50ms. -Clear: The height sensor PWM duty cycle has changed by less than 33% (3.3 * 10ms alert period) since its previous cycle for 500ms.

TAS2_a032
TAS2_a032_PWMerrorRL
Caution Alert
TAS2_a032 - PW Merror RL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every repeated fault and triggers the fault at a threshold of 50. The weighted counter decrements by 1 for every valid reading and clears the fault when it reaches 0. TAS2_a032_PWMerrorRL will trigger if any of the following faults are set: PWM_OVER_MAX_DUTY -Set:The height sensor PWM signal has had a duty cycle greater than 87.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle less than 87.5% for 500ms. PWM_UNDER_MIN_DUTY -Set: The height sensor PWM signal has had a duty cycle less than 12.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle greater than 12.5% for 500ms. PWM_OVER_MAX_PERIOD -Set: The height sensor PWM signal has had a period greater than 0.00131579 seconds for 50ms. -Clear:The height sensor PWM signal has had a period less than 0.00131579 seconds for 500ms. PWM_UNDER_MIN_PERIOD -Set: The height sensor PWM signal has had a period less than 0.00119048 seconds for 50ms. -Clear:The height sensor PWM signal has had a period greater than 0.00119048 seconds for 500ms. PWM_OVER_MAX_DELTA_DUTY (cannot be set if transitioning to/from 0 or 100% duty cycle) -Set: The height sensor PWM duty cycle has changed by more than 33% (3.3 * 10ms alert period) since its previous cycle for 50ms. -Clear: The height sensor PWM duty cycle has changed by less than 33% (3.3 * 10ms alert period) since its previous cycle for 500ms.

TAS2_a033
TAS2_a033_PWMerrorRR
Caution Alert
TAS2_a033 - PW Merror RR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every repeated fault and triggers the fault at a threshold of 50. The weighted counter decrements by 1 for every valid reading and clears the fault when it reaches 0. TAS2_a033_PWMerrorFL will trigger if any of the following faults are set: PWM_OVER_MAX_DUTY -Set:The height sensor PWM signal has had a duty cycle greater than 87.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle less than 87.5% for 500ms. PWM_UNDER_MIN_DUTY -Set: The height sensor PWM signal has had a duty cycle less than 12.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle greater than 12.5% for 500ms. PWM_OVER_MAX_PERIOD -Set: The height sensor PWM signal has had a period greater than 0.00131579 seconds for 50ms. -Clear:The height sensor PWM signal has had a period less than 0.00131579 seconds for 500ms. PWM_UNDER_MIN_PERIOD -Set: The height sensor PWM signal has had a period less than 0.00119048 seconds for 50ms. -Clear:The height sensor PWM signal has had a period greater than 0.00119048 seconds for 500ms. PWM_OVER_MAX_DELTA_DUTY (cannot be set if transitioning to/from 0 or 100% duty cycle) -Set: The height sensor PWM duty cycle has changed by more than 33% (3.3 * 10ms alert period) since its previous cycle for 50ms. -Clear: The height sensor PWM duty cycle has changed by less than 33% (3.3 * 10ms alert period) since its previous cycle for 500ms.

TAS2_a034
TAS2_a034_PWMshortFL
Caution Alert
TAS2_a034 - PW Mshort FL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every faulted reading and triggers the fault at a threshold of 50. Set: The front left (FL) height sensor PWM signal has had a duty cycle equal to 0% for 50ms. A weighted counter increments by 10 for every FAULT_TYPE_PWM_SHORT_CIRCUIT and triggers the fault at a threshold of 50. Clear: The front left (FL) height sensor PWM signal has had a duty cycle greater than 0% for 500ms. A weighted counter decrements (from threshold of 50) by 1 for every valid reading and clears the fault when it reaches 0.

TAS2_a035
TAS2_a035_PWMshortFR
Caution Alert
TAS2_a035 - PW Mshort FR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every faulted reading and triggers the fault at a threshold of 50. Set: The front right (FR) height sensor PWM signal has had a duty cycle equal to 0% for 50ms. A weighted counter increments by 10 for every FAULT_TYPE_PWM_SHORT_CIRCUIT and triggers the fault at a threshold of 50. Clear: The front right (FR) height sensor PWM signal has had a duty cycle greater than 0% for 500ms. A weighted counter decrements (from threshold of 50) by 1 for every valid reading and clears the fault when it reaches 0.

TAS2_a036
TAS2_a036_PWMshortRL
Caution Alert
TAS2_a036 - PW Mshort RL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every faulted reading and triggers the fault at a threshold of 50. Set: The rear left (RL) height sensor PWM signal has had a duty cycle equal to 0% for 50ms. A weighted counter increments by 10 for every FAULT_TYPE_PWM_SHORT_CIRCUIT and triggers the fault at a threshold of 50. Clear: The rear left (RL) height sensor PWM signal has had a duty cycle greater than 0% for 500ms. A weighted counter decrements (from threshold of 50) by 1 for every valid reading and clears the fault when it reaches 0.

TAS2_a037
TAS2_a037_PWMshortRR
Caution Alert
TAS2_a037 - PW Mshort RR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every faulted reading and triggers the fault at a threshold of 50. Set: The rear right (RR) height sensor PWM signal has had a duty cycle equal to 0% for 50ms. A weighted counter increments by 10 for every FAULT_TYPE_PWM_SHORT_CIRCUIT and triggers the fault at a threshold of 50. Clear: The rear right (RR) height sensor PWM signal has had a duty cycle greater than 0% for 500ms. A weighted counter decrements (from threshold of 50) by 1 for every valid reading and clears the fault when it reaches 0.

TAS2_a038
TAS2_a038_PWMopenFL
Caution Alert
TAS2_a038 - PW Mopen FL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every faulted reading and triggers the fault at a threshold of 50. Set: The front left (FL) height sensor PWM signal has had a duty cycle equal to 100% for 50ms. A weighted counter increments by 10 for every FAULT_TYPE_PWM_OPEN_CIRCUIT and triggers the fault at a threshold of 50. Clear: The front left (FL) height sensor PWM signal has had a duty cycle less than 100% for 500ms. A weighted counter decrements (from threshold of 50) by 1 for every valid reading and clears the fault when it reaches 0.

TAS2_a039
TAS2_a039_PWMopenFR
Caution Alert
TAS2_a039 - PW Mopen FR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every faulted reading and triggers the fault at a threshold of 50. Set: The front right (FR) height sensor PWM signal has had a duty cycle equal to 100% for 50ms. A weighted counter increments by 10 for every FAULT_TYPE_PWM_OPEN_CIRCUIT and triggers the fault at a threshold of 50. Clear: The front right (FR) height sensor PWM signal has had a duty cycle less than 100% for 500ms. A weighted counter decrements (from threshold of 50) by 1 for every valid reading and clears the fault when it reaches 0.

TAS2_a040
TAS2_a040_PWMopenRL
Caution Alert
TAS2_a040 - PW Mopen RL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every faulted reading and triggers the fault at a threshold of 50. Set: The rear left (RL) height sensor PWM signal has had a duty cycle equal to 100% for 50ms. A weighted counter increments by 10 for every FAULT_TYPE_PWM_OPEN_CIRCUIT and triggers the fault at a threshold of 50. Clear: The rear left (RL) height sensor PWM signal has had a duty cycle less than 100% for 500ms. A weighted counter decrements (from threshold of 50) by 1 for every valid reading and clears the fault when it reaches 0.

TAS2_a041
TAS2_a041_PWMopenRR
Caution Alert
TAS2_a041 - PW Mopen RR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every faulted reading and triggers the fault at a threshold of 50. Set: The rear right (RR) height sensor PWM signal has had a duty cycle equal to 100% for 50ms. A weighted counter increments by 10 for every FAULT_TYPE_PWM_OPEN_CIRCUIT and triggers the fault at a threshold of 50. Clear: The rear right (RR) height sensor PWM signal has had a duty cycle less than 100% for 500ms. A weighted counter decrements (from threshold of 50) by 1 for every valid reading and clears the fault when it reaches 0.

TAS2_a072
TAS2_a072_shortCircuit5VOnBoard
Caution Alert
TAS2_a072 - short Circuit5V On Board

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The on-board 5V supply on the Tesla Air Suspension (TAS) board is sensed to be shorted to ground. The alert checks for 5VS0 power supply faults every 100ms. If this is a persistent warning, there is likely an issue with the board.

TAS2_a073
TAS2_a073_underVoltage5VOnBoard
Caution Alert
TAS2_a073 - under Voltage5V On Board

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The on-board 5V supply on the Tesla Air Suspension (TAS) board is sensed to have low voltage. The alert checks for 5VS0 power supply faults every 100ms. If this is a persistent warning, there is likely an issue with the board.

TAS2_a077
TAS2_a077_pressureSigVTooLow
Caution Alert
TAS2_a077 - pressure Sig V Too Low

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The Tesla Air Suspension Controller (TAS) supplies the system pressure sensor (located in the valve block) with 5V, and observes the analog pressure signal voltage to evaluate the pressure. In normal operation of the pressure sensor, the signal should range from approximately 10-90% of the supply voltage. Set: The gallery pressure sensor signal is below 4% the supply voltage (nominally 5V). voltage < 0.2 V Clear: The gallery pressure sensor signal is above 4% the supply voltage (nominally 5V). voltage > 0.2 V To convert from percent to bar: p(bar) = 23.7248 * p(percent) - 1.375

TAS2_a078
TAS2_a078_pressureSigVTooHigh
Caution Alert
TAS2_a078 - pressure Sig V Too High

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The Tesla Air Suspension Controller (TAS) supplies the system pressure sensor (located in the valve block) with 5V, and observes the analog pressure signal voltage to evaluate the pressure. In normal operation of the pressure sensor, the signal should range from approximately 10-90% of the supply voltage. Set: The gallery pressure sensor signal is above 96% the supply voltage (nominally 5V). voltage > 4.8 V Clear: The gallery pressure sensor signal is below 96% the supply voltage (nominally 5V). voltage < 4.8 V 96% corresponds to ~22.4 bar To convert from percent to bar: p(bar) = 23.7248 * p(percent) - 1.375

TAS2_a080
TAS2_a080_shortCircuit5VHeight
Caution Alert
TAS2_a080 - short Circuit5V Height

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. An external 5V supply on the Tesla Air Suspension (TAS) board is sensed to be shorted to ground. This rail supplies 5V to the level sensors, so a bad supply or measurement may lead to unexpected operation. The alert checks for 5V power supply faults every 100ms.

TAS2_a081
TAS2_a081_underVoltage5VHeight
Caution Alert
TAS2_a081 - under Voltage5V Height

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. An external 5V supply on the Tesla Air Suspension (TAS) board is sensed to be too low. This rail supplies 5V to the level sensors, so a bad supply or measurement may lead to unexpected operation. The alert checks for 5V power supply faults every 100ms. If this is a persistent warning, there is likely an issue with the board.

TAS2_a082
TAS2_a082_overVoltage5VHeight
Caution Alert
TAS2_a082 - over Voltage5V Height

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. An external 5V supply on the Tesla Air Suspension (TAS) board is sensed to be too high. This rail supplies 5V to the level sensors, so a bad supply or measurement may lead to unexpected operation. The alert checks for 5V power supply faults every 100ms. If this is a persistent warning, there is likely an issue with the board.

TAS2_a083
TAS2_a083_shortCircuit5VAnalog
Caution Alert
TAS2_a083 - short Circuit5V Analog

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. An external 5V supply on the Tesla Air Suspension (TAS) board is sensed to be shorted to ground. This rail supplies 5V to the pressure sensor, so a bad supply or measurement may lead to unexpected operation. The alert checks for 5V power supply faults every 100ms.

TAS2_a084
TAS2_a084_underVoltage5VAnalog
Caution Alert
TAS2_a084 - under Voltage5V Analog

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. An external 5V supply on the Tesla Air Suspension (TAS) board is sensed to be too low. This rail supplies 5V to the pressure sensor, so a bad supply or measurement may lead to unexpected operation. The alert checks for 5V power supply faults every 100ms. If this is a persistent warning, there is likely an issue with the board.

TAS2_a085
TAS2_a085_overVoltage5VAnalog
Caution Alert
TAS2_a085 - over Voltage5V Analog

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. An external 5V supply on the Tesla Air Suspension (TAS) board is sensed to be too high. This rail supplies 5V to the pressure sensor, so a bad supply or measurement may lead to unexpected operation. The alert checks for 5V power supply faults every 100ms. If this is a persistent warning, there is likely an issue with the board.

TAS2_a093
TAS2_a093_OTPError
Caution Alert
TAS2_a093 - OTP Error

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for any errors with the Tesla Air Suspension Controller's (TASC) one time programmable memory (OTP) every 1000ms. Note: This alert does not disable any functionality and is for logging only. Set: There is any error reading the OTP. Clear: The OTP is read successfully.

TAS2_a094
TAS2_a094_DAS_MIA
Caution Alert
TAS2_a094 - DAS MIA

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a095
TAS2_a095_DIS_MIA
Caution Alert
TAS2_a095 - DIS MIA

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a096
TAS2_a096_IMU_MIA
Caution Alert
TAS2_a096 - IMU MIA

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a097
TAS2_a097_RCM_MIA
Caution Alert
TAS2_a097 - RCM MIA

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a098
TAS2_a098_MCU_MIA
Caution Alert
TAS2_a098 - MCU MIA

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a099
TAS2_a099_EFUSE_MIA
Caution Alert
TAS2_a099 - EFUSE MIA

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a100
TAS2_a100_SCCM_MIA
Caution Alert
TAS2_a100 - SCCM MIA

Tesla alert code in the Thermal Architecture System v2 (TAS2) module related to sccm mia.

TAS2_a101
TAS2_a101_ESP_MIA
Caution Alert
TAS2_a101 - ESP MIA

Tesla alert code in the Thermal Architecture System v2 (TAS2) module related to esp mia.

TAS2_a102
TAS2_a102_DI_MIA
Caution Alert
TAS2_a102 - DI MIA

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a103
TAS2_a103_GTW_MIA
Caution Alert
TAS2_a103 - GTW MIA

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a121
TAS2_a121_maxDutyFL
Caution Alert
TAS2_a121 - max Duty FL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a122
TAS2_a122_maxDutyFR
Caution Alert
TAS2_a122 - max Duty FR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a123
TAS2_a123_maxDutyRL
Caution Alert
TAS2_a123 - max Duty RL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a124
TAS2_a124_maxDutyRR
Caution Alert
TAS2_a124 - max Duty RR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a125
TAS2_a125_maxDutyReservoir
Caution Alert
TAS2_a125 - max Duty Reservoir

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a126
TAS2_a126_maxDutyExhaust
Caution Alert
TAS2_a126 - max Duty Exhaust

Tesla alert code in the Thermal Architecture System v2 (TAS2) module related to max duty exhaust.

TAS2_a127
TAS2_a127_maxDutyBoost
Caution Alert
TAS2_a127 - max Duty Boost

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a128
TAS2_a128_maxDutyCompressor
Caution Alert
TAS2_a128 - max Duty Compressor

Tesla alert code in the Thermal Architecture System v2 (TAS2) module related to max duty compressor.

TAS2_a129
TAS2_a129_openCircuitFL
Caution Alert
TAS2_a129 - open Circuit FL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for open circuit faults every 10ms. Voltage and current are measured by Tesla Air Suspension Controller (TASC) when the front left (FL) valve is commanded with 12V. Set: The FL valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6V current is sensed below 0.02A Clear: Single drive-rail cycle

TAS2_a130
TAS2_a130_openCircuitFR
Caution Alert
TAS2_a130 - open Circuit FR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the front right (FR) valve is commanded with 12V. Set: The FR valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6Vcurrent is sensed below 0.02A Clear: Single drive-rail cycle

TAS2_a131
TAS2_a131_openCircuitRL
Caution Alert
TAS2_a131 - open Circuit RL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the rear left (RL) valve is commanded with 12V. Set: The RL valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6Vcurrent is sensed below 0.02AClear: Single drive-rail cycle

TAS2_a132
TAS2_a132_openCircuitRR
Caution Alert
TAS2_a132 - open Circuit RR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the rear right (RR) valve is commanded with 12V. Set: The RR valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6Vcurrent is sensed below 0.02A Clear: Single drive-rail cycle

TAS2_a133
TAS2_a133_openCircuitReservoir
Caution Alert
TAS2_a133 - open Circuit Reservoir

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the reservoir valve is commanded with 12V. Set: The reservoir valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6Vcurrent is sensed below 0.02AClear: Single drive-rail cycle

TAS2_a134
TAS2_a134_openCircuitExhaust
Caution Alert
TAS2_a134 - open Circuit Exhaust

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the exhaust valve is commanded with 12V. Set: The exhaust valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6Vcurrent is sensed below 0.02AClear: Single drive-rail cycle

TAS2_a135
TAS2_a135_openCircuitBoost
Caution Alert
TAS2_a135 - open Circuit Boost

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the boost valve is commanded with 12V. Set:The boost valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6V current is sensed below 0.02AClear: Single drive-rail cycle

TAS2_a136
TAS2_a136_openCircuitCompressor
Caution Alert
TAS2_a136 - open Circuit Compressor

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. Vehicles without efuse/Vehicle Controller Front (VCFRONT): Tesla Air Suspension (TAS) has determined an open circuit condition on the compressor relay drive circuit. Vehicles with efuse/VCFRONT: efuse/VCFRONT has determined an open circuit condition on the compressor power drive circuit.

TAS2_a137
TAS2_a137_shortCircuitFL
Caution Alert
TAS2_a137 - short Circuit FL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for short circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the front left (FL) valve is commanded with 12V. Set: The FL valve is commanded and both of the following are true: voltage is sensed below 2.4Vcurrent is sensed below 0.02A or above 1.3AClear: Single drive-rail cycle

TAS2_a138
TAS2_a138_shortCircuitFR
Caution Alert
TAS2_a138 - short Circuit FR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for short circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the front right (FR) valve is commanded with 12V. Set: The FR valve is commanded and both of the following are true: voltage is sensed below 2.4Vcurrent is sensed below 0.02A or above 1.3AClear: Single drive-rail cycle

TAS2_a139
TAS2_a139_shortCircuitRL
Caution Alert
TAS2_a139 - short Circuit RL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for short circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Current (TASC) when the rear left (RL) valve is commanded with 12V. Set: The RL valve is commanded and both of the following are true: voltage is sensed below 2.4Vcurrent is sensed below 0.02A or above 1.3A Clear: Single drive-rail cycle

TAS2_a140
TAS2_a140_shortCircuitRR
Caution Alert
TAS2_a140 - short Circuit RR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for short circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the rear right (RR) valve is commanded with 12V. Set: The RR valve is commanded and both of the following are true: voltage is sensed below 2.4Vcurrent is sensed below 0.02A or above 1.3AClear: Single drive-rail cycle

TAS2_a141
TAS2_a141_shortCircuitReservoir
Caution Alert
TAS2_a141 - short Circuit Reservoir

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for short circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the reservoir valve is commanded with 12V. Set: The reservoir valve is commanded and both of the following are true: voltage is sensed below 2.4Vcurrent is sensed below 0.02A or above 1.3AClear: Single drive-rail cycle

TAS2_a142
TAS2_a142_shortCircuitExhaust
Caution Alert
TAS2_a142 - short Circuit Exhaust

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for short circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the exhaust valve is commanded with 12V. Set: The exhaust valve is commanded and both of the following are true: voltage is sensed below 2.4Vcurrent is sensed below 0.02A or above 1.3AClear: Single drive-rail cycle

TAS2_a143
TAS2_a143_shortCircuitBoost
Caution Alert
TAS2_a143 - short Circuit Boost

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for short circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the boost valve is commanded with 12V. Set: The boost valve is commanded and both of the following are true: voltage is sensed below 2.4Vcurrent is sensed below 0.02A or above 1.3AClear: Single drive-rail cycle

TAS2_a144
TAS2_a144_shortCircuitCompressor
Caution Alert
TAS2_a144 - short Circuit Compressor

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. Vehicles without efuse/Vehicle Controller Front (VCFRONT): Tesla Air Suspension (TAS) has determined a short circuit condition on the compressor relay drive circuit. Alert will be set if output is shorted to ground or shorted to 12V. Vehicles with efuse/VCFRONT: efuse/VCFRONT has determined a short circuit condition on the compressor power drive circuit.

TAS2_a162
TAS2_a162_compressorValveOpenGND
Caution Alert
TAS2_a162 - compressor Valve Open GND

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for disconnected ground to the exhaust/boost valves every 10ms. Set: If both of the following are true: Open circuit fault is true when a valve is commanded open.Short circuit fault is true when a valve is commanded close.Clear: Single drive-rail cycle

TAS2_a165
TAS2_a165_damperValveCompFL
Caution Alert
TAS2_a165 - damper Valve Comp FL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The front left compression damping valve circuit is open, shorted, or returns an unexpected resistance. The damper valve is located on the damper body in the wheel well. Compression is the top valve and rebound is the bottom valve. The front damper valves are connected via pigtail harness from the front harness. The damper valves are driven by the Tesla Air Suspension ECU. Set: An open circuit, short circuit, or unexpected resistance value is detected on the valve after startup, or if the damper current deviates from the commanded current over time (indicating an unexpected circuit behavior). Clear: Drive rail cycle or ECU power cycle.

TAS2_a166
TAS2_a166_damperValveRbndFL
Caution Alert
TAS2_a166 - damper Valve Rbnd FL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The front left rebound damping valve circuit is open, shorted, or returns an unexpected resistance. The damper valve is located on the damper body in the wheel well. Compression is the top valve and rebound is the bottom valve. The front damper valves are connected via pigtail harness from the front harness. The damper valves are driven by the Tesla Air Suspension ECU. Set: An open circuit, short circuit, or unexpected resistance value is detected on the valve after startup, or if the damper current deviates from the commanded current over time (indicating an unexpected circuit behavior). Clear: Drive rail cycle or ECU power cycle.

TAS2_a167
TAS2_a167_damperValveCompFR
Caution Alert
TAS2_a167 - damper Valve Comp FR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The front right compression damping valve circuit is open, shorted, or returns an unexpected resistance. The damper valve is located on the damper body in the wheel well. Compression is the top valve and rebound is the bottom valve. The front damper valves are connected via pigtail harness from the front harness. The damper valves are driven by the Tesla Air Suspension ECU. Set: An open circuit, short circuit, or unexpected resistance value is detected on the valve after startup, or if the damper current deviates from the commanded current over time (indicating an unexpected circuit behavior). Clear: Drive rail cycle or ECU power cycle.

TAS2_a168
TAS2_a168_damperValveRbndFR
Caution Alert
TAS2_a168 - damper Valve Rbnd FR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The front right rebound damping valve circuit is open, shorted, or returns an unexpected resistance. The damper valve is located on the damper body in the wheel well. Compression is the top valve, rebound is the bottom valve. The front damper valves are connected via pigtail harness from the front harness. The damper valves are driven by the Tesla Air Suspension ECU. Set: An open circuit, short circuit, or unexpected resistance value is detected on the valve after startup, or if the damper current deviates from the commanded current over time (indicating an unexpected circuit behavior). Clear: Drive rail cycle or ECU power cycle.

TAS2_a169
TAS2_a169_damperValveCompRL
Caution Alert
TAS2_a169 - damper Valve Comp RL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The rear left compression damping valve circuit is open, shorted, or returns an unexpected resistance. The damper valve is located on the damper body in the wheel well. Compression is the top valve and rebound is the bottom valve. The rear damper valves are connected directly to the subframe harness. The damper valves are driven by the Tesla Air Suspension ECU. Set: An open circuit, short circuit, or unexpected resistance value is detected on the valve after startup, or if the damper current deviates from the commanded current over time (indicating an unexpected circuit behavior). Clear: Drive rail cycle or ECU power cycle.

TAS2_a170
TAS2_a170_damperValveRbndRL
Caution Alert
TAS2_a170 - damper Valve Rbnd RL

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The rear left rebound damping valve circuit is open, shorted, or returns an unexpected resistance. The damper valve is located on the damper body in the wheel well. Compression is the top valve and rebound is the bottom valve. The rear damper valves are connected directly to the subframe harness. The damper valves are driven by the Tesla Air Suspension ECU. Set: An open circuit, short circuit, or unexpected resistance value is detected on the valve after startup, or if the damper current deviates from the commanded current over time (indicating an unexpected circuit behavior). Clear: Drive rail cycle or ECU power cycle.

TAS2_a171
TAS2_a171_damperValveCompRR
Caution Alert
TAS2_a171 - damper Valve Comp RR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The rear right compression damping valve circuit is open, shorted, or returns an unexpected resistance. The damper valve is located on the damper body in the wheel well. Compression is the top valve and rebound is the bottom valve. The rear damper valves are connected directly to the subframe harness. The damper valves are driven by the Tesla Air Suspension ECU. Set: An open circuit, short circuit, or unexpected resistance value is detected on the valve after startup, or if the damper current deviates from the commanded current over time (indicating an unexpected circuit behavior). Clear: Drive rail cycle or ECU power cycle.

TAS2_a172
TAS2_a172_damperValveRbndRR
Caution Alert
TAS2_a172 - damper Valve Rbnd RR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The rear right rebound damping valve circuit is open, shorted, or returns an unexpected resistance. The damper valve is located on the damper body in the wheel well. Compression is the top valve and rebound is the bottom valve. The rear damper valves are connected directly to the subframe harness. The damper valves are driven by the Tesla Air Suspension ECU. Set: An open circuit, short circuit, or unexpected resistance value is detected on the valve after startup, or if the damper current deviates from the commanded current over time (indicating an unexpected circuit behavior). Clear: Drive rail cycle or ECU power cycle.

TAS2_a200
TAS2_a200_jackModeActive
Caution Alert
TAS2_a200 - jack Mode Active

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert is set each time the Tesla Air Suspension (TAS) board is set to Jack mode or wakes while in Jack mode (Chassis bus turns on).

TAS2_a201
TAS2_a201_lowHVBattery
Caution Alert
TAS2_a201 - low HV Battery

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert is a load-shed request from Gateway (GTW) due to the voltage of the LV bus. Set: This alert is set when the GTW sends the CH_hvBatteryLow signal, which is a carry-over signal from Electronic Air Suspension (EAS). Despite the name of the alert, this message indicates to the air suspension controller that the LV system (not necessarily the LV battery or HV battery) is at a low voltage, and so it sends the controller into a limp mode to reduce the electrical loading on the LV system. It is likely to see this during a load-shed event where the LV system is not being properly supported by the DCDC. Clear: Clearing of the low high-voltage battery signal (CH_hvBatteryLow).

TAS2_a210
TAS2_a210_outOfRangeCalibration
Caution Alert
TAS2_a210 - out Of Range Calibration

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert indicates that the ride height sensor positions are in an unexpected range compared to a known default value, which is determined in firmware. It is meant to catch gross miscalibrations. This alert and yellow warning lamp indicate that the calibration on at least one corner is between 25 and 50mm away from the default. If (during ride height calibration) the operator enters a height measurement that results in an offset that is 25-50mm from the default offset, the calibration will be accepted but will cause the aforementioned alert to be set, with a yellow warning lamp. Operation will not be restricted.If the operator enters a height measurement that results in an offset that is more than +/-50mm from the default offset, the Unified Diagnostic Services (UDS) routine will fail and nothing will change. No alert will appear and no calibration information will be saved.Each vehicle will have the ride height sensor in a slightly different position due to tolerance stackup. This is why Tesla Air Suspension (TAS) allows for a +/-25mm window before setting the alert.

TAS2_a211
TAS2_a211_noRideHeightCalib
Caution Alert
TAS2_a211 - no Ride Height Calib

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert indicates that the air suspension controller does not have stored ride height calibration. This is expected for a "virgin" board but should not be seen after the suspension ride height has been successfully calibrated. The alert checks for height sensor calibration status once per second. Set: If height sensor calibration values are unavailable in memory, the alert is set. Clear: If height sensor calibration values become available in memory, the alert is cleared.

TAS2_a213
TAS2_a213_yellowWarningLamp
Caution Alert
TAS2_a213 - yellow Warning Lamp

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert only signifies that the yellow warning lamp is illuminated.

TAS2_a214
TAS2_a214_redWarningLamp
Caution Alert
TAS2_a214 - red Warning Lamp

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert only signifies that the red warning lamp is illuminated.

TAS2_a215
TAS2_a215_limpHomeMode10
Caution Alert
TAS2_a215 - limp Home Mode10

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a216
TAS2_a216_limpHomeMode20
Caution Alert
TAS2_a216 - limp Home Mode20

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a217
TAS2_a217_limpHomeMode30
Caution Alert
TAS2_a217 - limp Home Mode30

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a218
TAS2_a218_limpHomeMode40
Caution Alert
TAS2_a218 - limp Home Mode40

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a220
TAS2_a220_exhaustGalleryFault
Caution Alert
TAS2_a220 - exhaust Gallery Fault

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for exhaust gallery faults every 100ms. Set: After an exhaust procedure, gallery pressure stays above 5 Bar. Clear: After an exhaust procedure, gallery pressure decreases below 5 Bar. Note: An exhaust procedure is considered completed if one of the following is true: After opening the exhaust valve, gallery pressure has been constant within +/- 0.05 Bar for 50ms.The exhaust valve has been open for more than 2.5 seconds.The gallery is the volume within the valve block that gets pressurized prior to filling the reservoir or an air spring. The gallery is where the pressure sensor measures pressure when other components open their valves to connect to the gallery. The gallery is exhausted to atmosphere after a filling or a pressure check operation to reduce stress on the system. This is done by closing all valves except the exhaust valve, allowing the gallery pressure to decrease. The decrease in gallery pressure is limited by an internal check valve in the compressor, which is rated above atmospheric pressure.

TAS2_a221
TAS2_a221_valveLeakDetected
Caution Alert
TAS2_a221 - valve Leak Detected

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert indicates that the gallery (the shared air volume within the valve block) is observing an increasing pressure reading with all valves commanded closed.

TAS2_a222
TAS2_a222_compressorPrefillFault
Caution Alert
TAS2_a222 - compressor Prefill Fault

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for compressor prefill faults every 100ms. Set: Compressor prefill will timeout during a prefill operation if the pressure derivative remains under 1 bar/second for 10 seconds. Clear: Single drive-rail cycle Note: A prefill operation is performed before opening the valves to an air spring or the reservoir. Prefill works by activating the compressor with the spring and reservoir valves closed, so that the gallery pressure increases. This reduces the change in pressure upon opening of the valves, similar to the precharge sequence for the high-voltage battery or on-board chargers. Prefill will fail if: a valve is open or leaking (pressure escapes from the gallery) the compressor does not run compressed air escapes before the valve block

TAS2_a223
TAS2_a223_blockedAirline
Caution Alert
TAS2_a223 - blocked Airline

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for blocked airline faults every 100ms. Set: The pressure derivative exceeds 4 Bar/s for 1 second and Tesla Air Suspension (TAS) is in one of the following states: TAS_state = Fill_reservoir_from_Compressor TAS_state = Fill_spring_reservoir_from_Compressor TAS_state = Fill_spring_from_Compressor TAS_state = Fill_spring_from_Boost Clear: Single drive-rail cycle When the system is functioning normally, the gallery pressure should not climb this fast while filling a spring or the reservoir.

TAS2_a224
TAS2_a224_openAirline
Caution Alert
TAS2_a224 - open Airline

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for blocked airline faults every 100ms. Set: The pressure derivative is less than 0.1 Bar/second for 10 seconds and Tesla Air Suspension (TAS) is in one of the following states: TAS_state = Fill_reservoir_from_CompressorTAS_state = Fill_spring_reservoir_from_CompressorTAS_state = Fill_spring_from_CompressorTAS_state = Fill_spring_from_Boost Clear: Single drive-rail cycle When the system is functioning normally, the gallery pressure should rise faster than this while filling a spring or the reservoir.

TAS2_a225
TAS2_a225_galleryPressureTooHigh
Caution Alert
TAS2_a225 - gallery Pressure Too High

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for high gallery pressure faults every 100ms. Set: Gallery pressure is greater than 19 bar for 1 second and Tesla Air Suspension (TAS) is in one of the following states: TAS_state = Fill_reservoir_from_CompressorTAS_state = Fill_spring_reservoir_from_CompressorTAS_state = Fill_spring_from_CompressorTAS_state = Fill_spring_from_Boost Clear: Single drive-rail cycle This indicates that the gallery pressure (where the pressure sensor is located) is over 19 bar, and has stayed at over 19 bar for one second. The system pressure for TAS is 18 bar, so while the system is functioning normally, pressure should never be over 19 bar, especially for over one second.

TAS2_a227
TAS2_a227_PWMfastDetectFR
Caution Alert
TAS2_a227 - PW Mfast Detect FR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. Alert is set to indicate that the front right (FR) height sensor temporarily faulted when 100%, 0%, or a large delta in the duty cycle was read from the front left (FL) pulse width modulation (PWM) height-sensor. Duty cycle of 100% indicates an open circuit. Duty cycle of 0% indicates a short to ground. The alert will clear when one second of expected values is received from the FL height-sensor.

TAS2_a229
TAS2_a229_PWMfastDetectRR
Caution Alert
TAS2_a229 - PW Mfast Detect RR

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. Alert is set to indicate that the rear right (RR) height sensor temporarily faulted when 100%, 0%, or a large delta in duty cycle was read from the RR pulse width modulation (PWM) height-sensor. Duty cycle of 100% indicates an open circuit. Duty cycle of 0% indicates a short to ground. The alert will clear when one second of expected values is received from the RR height-sensor.

TAS2_a290
TAS2_a290_twistSustainedAtSpeed
Caution Alert
TAS2_a290 - twist Sustained At Speed

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for twistSustainedAtSpeed faults every 100ms. Twist indicates that two diagonal corners are higher than the other two and the chassis is reporting a twisted state - as if one wheel was parked on a large block. At speed, twist should not be observed because no road surface can hold the vehicle in a twisted state while in motion. Twist is calculated using the four corner heights: front right (FR), front left (FL), rear right (RR), and rear left (RL). Twist = | (FL+RR)-(FR+RL) | Set: When vehicle speed is greater 10mph AND twist is greater than 20mm for 10 seconds. Clear: When vehicle speed is less than 10mph OR twist is less than 20mm.

TAS2_a295
TAS2_a295_targetHeightNotMet
Caution Alert
TAS2_a295 - target Height Not Met

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for targetHeightNotMet faults every 100ms.

TAS2_a296
TAS2_a296_chassisTypeMismatch
Caution Alert
TAS2_a296 - chassis Type Mismatch

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. Tesla Air Suspension 2 (TAS2) uses a common PCBA/Hardware ID for Model S and Model X, but uses different software applications (.hex files / configs) between the two vehicle types. If this alert is active, the chassis type of the firmware on the controller does not match the chassis type received on a car area network (CAN). Damping control will enter a backup state and endstop protection will not be active. Set: GTW_chassisType does not match the internal chassisType of the firmware on the controller. Clear: GTW_chassisType matches the internal chassisType of the firmware on the controller.

TAS2_a297
TAS2_a297_vinMismatch
Caution Alert
TAS2_a297 - VIN Mismatch

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. Tesla Air Suspension 2 (TAS2) uses a VIN learn because the system learns the damper travel endstops to compensate for any differences between height calibrations and nonlinearity between vehicles. The VIN learned to the controller does not match the VIN received on a car area network (CAN). Learned endstops may be incorrect. Damping control will enter a backup state and endstop protection will not be active. Set: The VIN learned to the controller does not match the VIN received on CAN. Clear: A VIN is saved by performing ride height calibration. Note: If using the normal air suspension calibration panel in TBX2 clears TAS2_a297_vinMismatch, perform another calibration using the "Air Suspension Calibration (Advanced)" Panel.

TAS2_a298
TAS2_a298_vinNotLearned
Caution Alert
TAS2_a298 - VIN Not Learned

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. Tesla Air Suspension 2 (TAS2) uses a VIN learn because the system learns the damper travel endstops to compensate for any differences between height calibrations and nonlinearity between vehicles. A VIN has not been saved to the controller. Damping control will enter a backup state and endstop protection will not be active. This is expected for a new ECU that has just been installed into a vehicle, or on a vehicle where the ride height calibration has been cleared. Set: The VIN learned to the controller does not match the VIN received on a car area network (CAN). Clear: A VIN is saved by performing ride height calibration.

TAS2_a311
TAS2_a311_accelsMIA
Caution Alert
TAS2_a311 - accels MIA

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None

TAS2_a312
TAS2_a312_rotationalRatesMIA
Caution Alert
TAS2_a312 - rotational Rates MIA

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. None