TESLA Charging

Tesla CHG Alert Codes

Charger reference page with 114 Tesla alert codes, 107 detailed descriptions, severity counts, and diagnostic context.

84
Critical
14
Warning
0
Caution
16
Info

What the CHG system covers

Charger alerts belong to Tesla's proprietary diagnostic alert system and are grouped under the charging category.

Read all active alerts together instead of diagnosing a single code in isolation.
Check recent service, firmware updates, and low-voltage battery condition.
Use Tesla Service or a qualified EV technician for safety-critical systems.

Alert type breakdown

Fault 84 Unknown 14 Warning 14 Diagnostic 2

Tesla CHG code list

Rows with a linked code have a dedicated detail page.

Download CSV
Code Severity Type Description
CHG_d001
CHG_d001_replaceCharger
Info Diagnostic
CHG_d001 - replace Charger

Tesla diagnostic code in the Charger (CHG) module. The alert indicates a potential internal hardware issue with the charger.

CHG_d011
CHG_d011_proxRationality
Info Diagnostic
CHG_d011 - prox Rationality

Tesla diagnostic code in the Charger (CHG) module related to prox rationality.

CHG_f001
CHG_f001_hwBuck
Critical Fault
CHG_f001 - HW Buck

Tesla fault code in the Charger (CHG) module. The charger reports a fault at the buck stage due to a detected over voltage condition.

CHG_f002
CHG_f002_hwBoost
Critical Fault
CHG_f002 - HW Boost

Tesla fault code in the Charger (CHG) module. This alert indicates the charger boost voltage is not at the expected level.

CHG_f009
CHG_f009_hwFCWeld
Critical Fault
CHG_f009 - HW FC Weld

Tesla fault code in the Charger (CHG) module. The charger's Complex Programmable Logic Device (CPLD) has detected a fast charge (FC) contactor condition that indicates the contactors are welded.

CHG_f010
CHG_f010_hwIllegalFCRequest
Critical Fault
CHG_f010 - HW Illegal FC Request

Tesla fault code in the Charger (CHG) module. This alert is set when the charger's Complex Programmable Logic Device (CPLD) blocks the closure of the Fast Charge (FC) contactors because of another condition.

CHG_f011
CHG_f011_hwVInOV
Critical Fault
CHG_f011 - HW V In OV

Tesla fault code in the Charger (CHG) module. The charging hardware detected that the input voltage was too high. If this alert is present, there may be an issue with the power source, charger, or an issue with a high voltage (HV). If any of these issues are present, the pack contactors may open unexpectedly while charging.

CHG_f012
CHG_f012_hwFastChargeDriver
Critical Fault
CHG_f012 - HW Fast Charge Driver

Tesla fault code in the Charger (CHG) module. The Fast Charger (FC) contactor drive circuit has shorted to ground while the contactors are requesting to be closed.

CHG_f014
CHG_f014_hwThermal2
Critical Fault
CHG_f014 - HW Thermal2

Tesla fault code in the Charger (CHG) module. This alert indicates there is a problem in the charger coolant system, which could include a valve or line.

CHG_f015
CHG_f015_hwAntispark
Critical Fault
CHG_f015 - HW Antispark

Tesla fault code in the Charger (CHG) module related to hw antispark.

CHG_f016
CHG_f016_hwVOutOV
Critical Fault
CHG_f016 - HW V Out OV

Tesla fault code in the Charger (CHG) module. The hardware detected that the output voltage was too high. If this alert is present, there may be an issue with the charger or there may be a blown fuse in the high voltage junction box (HVJB).

CHG_f017
CHG_f017_hwIntermediateBus
Critical Fault
CHG_f017 - HW Intermediate Bus

Tesla fault code in the Charger (CHG) module. The intermediate bus voltage between the charger and high voltage (HV) battery pack is above the expected threshold.

CHG_f018
CHG_f018_hwLineOC
Critical Fault
CHG_f018 - HW Line OC

Tesla fault code in the Charger (CHG) module. The charging process was interrupted by the complex programmable logic device (CPLD) due to a very sudden increase of line current above the limit threshold. The alert may be falsely set due to extreme AC line voltage disturbances from other equipment. The Gen 1 charger spec defines the alert as line peak over-current trip level shall be <= 85A with a response time < 1us. The Gen 2 charger spec defines the alert as greater than 33A (tolerance of +/- 1.7A) per phase board.

CHG_f019
CHG_f019_hwIBatOC
Critical Fault
CHG_f019 - HW I Bat OC

Tesla fault code in the Charger (CHG) module. The charge current output to the high voltage (HV) battery is over the specified limit. The nominal trip conditions for each respective charger generation: Gen 1: 49.7A Gen 2: 29.9 +/- 1.7A Gen 3: 32.3A

CHG_f020
CHG_f020_hwHVIL
Critical Fault
CHG_f020 - HW HVIL

Tesla fault code in the Charger (CHG) module. There is resistance in the high voltage interlock loop (HVIL) due to the presence of a steady state, intermittent, or temperature issue.

CHG_f021
CHG_f021_15V
Critical Fault
CHG_f021 - 15V

Tesla fault code in the Charger (CHG) module related to 15v.

CHG_f022
CHG_f022_hw12VUV
Critical Fault
CHG_f022 - hw12VUV

Tesla fault code in the Charger (CHG) module. This alert indicates that the charging hardware has detected that the 12V battery voltage is too low.

CHG_f023
CHG_f023_hwReset
Critical Fault
CHG_f023 - HW Reset

Tesla fault code in the Charger (CHG) module. The charger detected a reset event in a phase board DSP.

CHG_f024
CHG_f024_VLineOVPk
Critical Fault
CHG_f024 - V Line OV Pk

Tesla fault code in the Charger (CHG) module. The peak line voltage is over the maximum threshold.

CHG_f025
CHG_f025_VLineUV
Critical Fault
CHG_f025 - V Line UV

Tesla fault code in the Charger (CHG) module. This alert indicates the charger measured that the input AC voltage was too low.

CHG_f026
CHG_f026_VOutOV
Critical Fault
CHG_f026 - V Out OV

Tesla fault code in the Charger (CHG) module. This article indicates the voltage output to the HV battery pack is over the maximum threshold.

CHG_f027
CHG_f027_VOutUV
Critical Fault
CHG_f027 - V Out UV

Tesla fault code in the Charger (CHG) module. The voltage output to the high voltage (HV) battery pack is under the minimum threshold.

CHG_f028
CHG_f028_igbtOT
Critical Fault
CHG_f028 - igbt OT

Tesla fault code in the Charger (CHG) module. The temperature has exceeded the safe threshold in the Insulated Gate Bipolar Transistor (IGBT).

CHG_f030
CHG_f030_VLineFreqOF
Critical Fault
CHG_f030 - V Line Freq OF

Tesla fault code in the Charger (CHG) module. The input line frequency is above the expected maximum threshold.

CHG_f031
CHG_f031_VLineFreqUF
Critical Fault
CHG_f031 - V Line Freq UF

Tesla fault code in the Charger (CHG) module. This alert indicates the input line frequency is below the expected minimum threshold.

CHG_f034
CHG_f034_swHVIL
Critical Fault
CHG_f034 - SW HVIL

Tesla fault code in the Charger (CHG) module. There is a resistance issue in the High Voltage Interlock Loop (HVIL).

CHG_f035
CHG_f035_pilotRationality
Critical Fault
CHG_f035 - pilot Rationality

Tesla fault code in the Charger (CHG) module. The pilot signal from the electric vehicle supply equipment (EVSE), as sensed by the charger, is not within the expected limits. If this alert is present, there may be a malfunction with either the pilot voltage or the signal frequency.

CHG_f039
CHG_f039_12V
Critical Fault
CHG_f039 - 12V

Tesla fault code in the Charger (CHG) module. The 12V measurement detected by the charger is not within the expected limits.

CHG_f040
CHG_f040_lostCommsGTW
Critical Fault
CHG_f040 - lost Comms GTW

Tesla fault code in the Charger (CHG) module. There is a Gateway (GTW) CAN communication issue.

CHG_f041
CHG_f041_lostCommsBMS
Critical Fault
CHG_f041 - lost Comms BMS

Tesla fault code in the Charger (CHG) module. The charger is no longer receiving controller area network (CAN) traffic from the high votlage (HV) battery.

CHG_f042
CHG_f042_lostCommsCP
Critical Fault
CHG_f042 - lost Comms CP

Tesla fault code in the Charger (CHG) module. There is a charge port communication issue.

CHG_f043
CHG_f043_canRationality
Critical Fault
CHG_f043 - CAN Rationality

Tesla fault code in the Charger (CHG) module. The firmware version is not coherent with the charger configuration.

CHG_f045
CHG_f045_invalidState
Critical Fault
CHG_f045 - invalid State

Tesla fault code in the Charger (CHG) module related to invalid state.

CHG_f046
CHG_f046_lostCommsPLC
Critical Fault
CHG_f046 - lost Comms PLC

Tesla fault code in the Charger (CHG) module related to lost comms plc.

CHG_f048
CHG_f048_FCWeldCheckState
Critical Fault
CHG_f048 - FC Weld Check State

Tesla fault code in the Charger (CHG) module. The fast charger contactors are detected by the charger to be in a welded state.

CHG_f049
CHG_f049_invalidChargeReq
Critical Fault
CHG_f049 - invalid Charge Req

Tesla fault code in the Charger (CHG) module. The charger mainstate is expected to transition to precharge or enable within 5 seconds of the previous state. If the transition does not occur within this time frame, the alert is set.

CHG_f051
CHG_f051_FCStateFault
Critical Fault
CHG_f051 - FC State Fault

Tesla fault code in the Charger (CHG) module. If the Gen 2 connector is unplugged before the set end of charge, state faults are common.

CHG_f053
CHG_f053_networkManagement
Critical Fault
CHG_f053 - network Management

Tesla fault code in the Charger (CHG) module related to network management.

CHG_f054
CHG_f054_interruptTime
Critical Fault
CHG_f054 - interrupt Time

Tesla fault code in the Charger (CHG) module. The charger application code has exceeded its allotted execution time.

CHG_f055
CHG_f055_VLineDischarge
Critical Fault
CHG_f055 - V Line Discharge

Tesla fault code in the Charger (CHG) module. The charger is measuring voltage on the incoming line when it is not expected.

CHG_f056
CHG_f056_5VPower
Critical Fault
CHG_f056 - 5V Power

Tesla fault code in the Charger (CHG) module. The 5V supply is not functioning as expected.

CHG_f057
CHG_f057_VLineOV
Critical Fault
CHG_f057 - V Line OV

Tesla fault code in the Charger (CHG) module. This alert indicates the line voltage exceeds the alternating current (AC) root mean squared (RMS) line voltage threshold of 305V.

CHG_f058
CHG_f058_watchdogreset
Critical Fault
CHG_f058 - watchdogreset

Tesla fault code in the Charger (CHG) module. This alert is expected any time the module has been reset.?

CHG_f060
CHG_f060_FCCntrVcheck
Critical Fault
CHG_f060 - FC Cntr Vcheck

Tesla fault code in the Charger (CHG) module. This alert indicates there is a mismatch between the fastcharge contactor power coming from the Battery Management System (BMS) and the Controller Area Network (CAN) signal state reported by the BMS.

CHG_f061
CHG_f061_FCAuxCntrRationality
Critical Fault
CHG_f061 - FC Aux Cntr Rationality

Tesla fault code in the Charger (CHG) module. This alert indicates that the auxiliary contactor status reported in firmware is not coherent with fast charger auxiliary control.

CHG_f062
CHG_f062_FCPosCntrWelded
Critical Fault
CHG_f062 - FC Pos Cntr Welded

Tesla fault code in the Charger (CHG) module. The charger could not determine the state of the fast charge contactors, or the fast charge contactors seem to be in a welded state. With Gen 1 and Gen 2 chargers, this alert is always set along with CHG_a063_FCNegCntrWelded.

CHG_f063
CHG_f063_FCNegCntrWelded
Critical Fault
CHG_f063 - FC Neg Cntr Welded

Tesla fault code in the Charger (CHG) module. This alert indicates the charger could not determine the state of the fast charge contactors, or if the fast charge contactors seem to be in a welded state. With Gen 1 and Gen 2 chargers, this alert is always set along with a062_FCPosCntrWelded.

CHG_f065
CHG_f065_FCCntrRationalitycheck
Critical Fault
CHG_f065 - FC Cntr Rationalitycheck

Tesla fault code in the Charger (CHG) module. The fast charger (FC) contactors do not match their respective auxiliary contact feedback state in relation to each other.

CHG_f066
CHG_f066_unexpectedVintBehavior
Critical Fault
CHG_f066 - unexpected Vint Behavior

Tesla fault code in the Charger (CHG) module. The charger intermediate voltage reading is unexpected.

CHG_f068
CHG_f068_heatsinkTempSlope
Critical Fault
CHG_f068 - heatsink Temp Slope

Tesla fault code in the Charger (CHG) module. The heatsink temperature is increasing at a rate above the threshold rate.

CHG_f070
CHG_f070_inputVoltMismatch
Critical Fault
CHG_f070 - input Volt Mismatch

Tesla fault code in the Charger (CHG) module. The temperature reading in the heatsink is over the threshold.

CHG_f071
CHG_f071_chargeThermalLimit
Critical Fault
CHG_f071 - charge Thermal Limit

Tesla fault code in the Charger (CHG) module. There is excessive heat within the charging unit.

CHG_f072
CHG_f072_assertion
Critical Fault
CHG_f072 - assertion

Tesla fault code in the Charger (CHG) module related to assertion.

CHG_f073
CHG_f073_unexpectedVoutBehavior
Critical Fault
CHG_f073 - unexpected Vout Behavior

Tesla fault code in the Charger (CHG) module. The output charger voltage is not reading in the expected range.

CHG_f074
CHG_f074_cpldFaulted
Critical Fault
CHG_f074 - cpld Faulted

Tesla fault code in the Charger (CHG) module. The complex programmable logic device (CPLD) has faulted according to the charger (CHG).

CHG_f075
CHG_f075_stateTransitionDenied
Critical Fault
CHG_f075 - state Transition Denied

Tesla fault code in the Charger (CHG) module. Charging was not allowed to proceed because of a blocking alert.

CHG_f076
CHG_f076_iLineOCPk
Critical Fault
CHG_f076 - i Line OC Pk

Tesla fault code in the Charger (CHG) module. This alert indicates the peak line current is over the maximum threshhold.

CHG_f077
CHG_f077_iLineOCRMS
Critical Fault
CHG_f077 - i Line OCRMS

Tesla fault code in the Charger (CHG) module. The RMS line current is over the maximum threshhold.

CHG_f079
CHG_f079_GFCI
Critical Fault
CHG_f079 - GFCI

Tesla fault code in the Charger (CHG) module. The charger has detected a current flowing down an unintended path. Note: This alert is only applicable to vehicles equipped with Gen 2 chargers.

CHG_f080
CHG_f080_vIntOutofRange
Critical Fault
CHG_f080 - v Int Outof Range

Tesla fault code in the Charger (CHG) module. The internal bus voltage measured inside the charger is out of range. If this alert is present, there may be an internal failure, a surge, or an incompatible high voltage source connected to the AC side, which would make its way to the internal bus.

CHG_f081
CHG_f081_iacRegulation
Critical Fault
CHG_f081 - iac Regulation

Tesla fault code in the Charger (CHG) module. There is an issue with the charger line current regulation.

CHG_f082
CHG_f082_vIntRegulation
Critical Fault
CHG_f082 - v Int Regulation

Tesla fault code in the Charger (CHG) module. There is a problem with the regulation of intermediate charger voltage.

CHG_f083
CHG_f083_allPhasesFaulted
Critical Fault
CHG_f083 - all Phases Faulted

Tesla fault code in the Charger (CHG) module. This alert is set if all active phase boards have used up their retries and are in a faulted state. The cause is often exterior to the charger, and it is unlikely multiple phase boards break simultaneously. Events that impact multiple phase boards at once could be issues related to charge cables, input power, or faults on the high voltage (HV) rails.

CHG_f084
CHG_f084_vOutRegulation
Critical Fault
CHG_f084 - v Out Regulation

Tesla fault code in the Charger (CHG) module. There is a malfunction with the charger output voltage.

CHG_f085
CHG_f085_adcReference
Critical Fault
CHG_f085 - ADC Reference

Tesla fault code in the Charger (CHG) module. This alert indicates there is a condition affecting the voltage sensor reading at the analog to digital converter (ADC).

CHG_f089
CHG_f089_iLineRationality
Critical Fault
CHG_f089 - i Line Rationality

Tesla fault code in the Charger (CHG) module. The charger is detecting a line current error.

CHG_f090
CHG_f090_vLineRationality
Critical Fault
CHG_f090 - v Line Rationality

Tesla fault code in the Charger (CHG) module. This alert is set when the measured line voltage offset is above a maximum threshhold.

CHG_f091
CHG_f091_proximityRationality
Critical Fault
CHG_f091 - proximity Rationality

Tesla fault code in the Charger (CHG) module. This alert indicates the primary charger has measured a value outside of the normal ranges.

CHG_f092
CHG_f092_vOutRationality
Critical Fault
CHG_f092 - v Out Rationality

Tesla fault code in the Charger (CHG) module. Output voltage is not within the expected range.

CHG_f093
CHG_f093_vIntRationality
Critical Fault
CHG_f093 - v Int Rationality

Tesla fault code in the Charger (CHG) module. The charger is detecting an intermediate voltage error.

CHG_f094
CHG_f094_igbtTempRationality
Critical Fault
CHG_f094 - igbt Temp Rationality

Tesla fault code in the Charger (CHG) module. The charger is detecting an insulated-gate bipolar transistor (IGBT) temperature error.

CHG_f095
CHG_f095_htsinkTempRationality
Critical Fault
CHG_f095 - htsink Temp Rationality

Tesla fault code in the Charger (CHG) module. The charger is detecting an error in the heatsink temperature.

CHG_f096
CHG_f096_ambientTempRationality
Critical Fault
CHG_f096 - ambient Temp Rationality

Tesla fault code in the Charger (CHG) module. The charger is detecting an ambient temperature irregularity.

CHG_f097
CHG_f097_hvilRationality
Critical Fault
CHG_f097 - hvil Rationality

Tesla fault code in the Charger (CHG) module. This alert indicates the charger is detecting a High Voltage Interlock Loop (HVIL) current error.

CHG_f098
CHG_f098_iOutRationality
Critical Fault
CHG_f098 - i Out Rationality

Tesla fault code in the Charger (CHG) module. There is a discrepancy between the charger output current and the high voltage (HV) battery current.

CHG_f099
CHG_f099_noFlowDetected
Critical Fault
CHG_f099 - no Flow Detected

Tesla fault code in the Charger (CHG) module. The inlet side of the charger is hotter than the outlet side, and charging has been stopped. If this alert is present, charging will not be possible for one minute to prevent repeated charge starts with no coolant flow to avoid ratcheting up the temperature.

CHG_f100
CHG_f100_hw15VUV
Critical Fault
CHG_f100 - hw15VUV

Tesla fault code in the Charger (CHG) module. One of the charger phase board (CHGPH) electronic control unit (ECU) is sensing a failed 15V power supply which will prevent charging. The 15V is boosted from a 12V power supply on the VI board.

CHG_f102
CHG_f102_lostCommsMaster
Critical Fault
CHG_f102 - lost Comms Master

Tesla fault code in the Charger (CHG) module. This alert suggests that there is an internal communication problem between the charger's vehicle interface processor and the primary charger.

CHG_f103
CHG_f103_lostCommsSlave
Critical Fault
CHG_f103 - lost Comms Slave

Tesla fault code in the Charger (CHG) module. This alert indicates there is an internal communication malfunction between the charger's vehicle interface processor and the secondary charger.

CHG_f104
CHG_f104_magneticsOT
Critical Fault
CHG_f104 - magnetics OT

Tesla fault code in the Charger (CHG) module. There is a problem with the charger output voltage reading.

CHG_f105
CHG_f105_magTempRationality
Critical Fault
CHG_f105 - mag Temp Rationality

Tesla fault code in the Charger (CHG) module. There is a malfunction with the voltage sensor reading at the analog to digital converter (ADC).

CHG_f106
CHG_f106_gfciRationality
Critical Fault
CHG_f106 - gfci Rationality

Tesla fault code in the Charger (CHG) module. The charger ground fault circuit interrupter (GFCI) is not behaving as expected.

CHG_f107
CHG_f107_cpldRationality
Critical Fault
CHG_f107 - cpld Rationality

Tesla fault code in the Charger (CHG) module. The software version running on the charger does not match the complex programmable logic device (CPLD) version running on the charger.

CHG_f109
CHG_f109_resetAttemptInEnable
Critical Fault
CHG_f109 - reset Attempt In Enable

Tesla fault code in the Charger (CHG) module. An attempt has been made to use the unified diagnostic services (UDS) reset command while actively charging.

CHG_f110
CHG_f110_busOff
Critical Fault
CHG_f110 - bus Off

Tesla fault code in the Charger (CHG) module. The charger has detected a controller area network (CAN) bus communication error.

CHG_f125
CHG_f125_leakageTestFailure
Critical Fault
CHG_f125 - leakage Test Failure

Tesla fault code in the Charger (CHG) module. This fault indicates that the voltage decay after the supercharger external isolation test has happened too quickly. During supercharger startup, the supercharger will open the output contactors after performing the external isolation test at 300V. The vehicle then monitors the time it takes for the 300V to decay. If the decay time is sufficient, the start-up sequence proceeds. The purpose of this test is to check the common mode isolation (DC+ to DC-) of the high voltage chain from the supercharger cabinet to the vehicle's fast charge contactors.

CHG_u001
CHG_u001_LineImpedanceHigh
Info Unknown
CHG_u001 - Line Impedance High

Tesla unknown code in the Charger (CHG) module. The line impedance is high or the line voltage is dropping significantly from another source drawing current on the same circuit. If this alert is present, the charging current is reduced by 25%.

CHG_u002
CHG_u002_LineImpedanceTooHigh
Info Unknown
CHG_u002 - Line Impedance Too High

Tesla unknown code in the Charger (CHG) module. The line impedance is too high, or the line voltage is dropping significantly from another source drawing current on the same circuit. If this alert is present, the voltage, which is monitored continuously during charging, has dropped by 14% or more for a period longer than 1 second from the initial voltage sample value that was taken at the beginning of charge before current started flowing and the vehicle will not be able to charge.

CHG_u003
CHG_u003_chargeThermalLimit
Info Unknown
CHG_u003 - charge Thermal Limit

Tesla unknown code in the Charger (CHG) module. This alert indicates charge current is limited due to excessive heat.

CHG_u004
CHG_u004_wallPowerRemoval
Info Unknown
CHG_u004 - wall Power Removal

Tesla unknown code in the Charger (CHG) module. The charger has detected a loss of wall power.

CHG_u005
CHG_u005_proxLatchedNoPilot
Info Unknown
CHG_u005 - prox Latched No Pilot

Tesla unknown code in the Charger (CHG) module. This alert indicates that the presence of a charge cable was detected, but no pilot signal was detected.

CHG_u006
CHG_u006_latchDownProxLatched
Info Unknown
CHG_u006 - latch Down Prox Latched

Tesla unknown code in the Charger (CHG) module. The presence of a charge cable was detected (via the proximity signal) and the latch was down.

CHG_u007
CHG_u007_chargeCableFault
Info Unknown
CHG_u007 - charge Cable Fault

Tesla unknown code in the Charger (CHG) module. This alert is set when the pilot signal coming from the charging station is set to a value that indicates a charging station issue.

CHG_u008
CHG_u008_cableNotLockedILimited
Info Unknown
CHG_u008 - cable Not Locked I Limited

Tesla unknown code in the Charger (CHG) module. None

CHG_u009
CHG_u009_FCHardwareNotInstalled
Info Unknown
CHG_u009 - FC Hardware Not Installed

Tesla unknown code in the Charger (CHG) module. This alert indicates that the hardware for fast charging (FC) has not been installed or that the configuration for fast charging has not been set up properly.

CHG_u010
CHG_u010_BadChargeCable
Info Unknown
CHG_u010 - Bad Charge Cable

Tesla unknown code in the Charger (CHG) module. There is unexpected AC voltage at the charge port inlet.

CHG_u012
CHG_u012_PilotCurrentReduced
Info Unknown
CHG_u012 - Pilot Current Reduced

Tesla unknown code in the Charger (CHG) module. The charging pilot current was reduced. If this alert is present, there may be external charging equipment connected to the vehicle that was not provided by Tesla.

CHG_u013
CHG_u013_chargeStoppedNoPilot
Info Unknown
CHG_u013 - charge Stopped No Pilot

Tesla unknown code in the Charger (CHG) module. The pilot was lost after charging started.

CHG_u014
CHG_u014_connectorFault
Info Unknown
CHG_u014 - connector Fault

Tesla unknown code in the Charger (CHG) module. There is an issue with the electric vehicle supply equipment (EVSE).

CHG_u015
CHG_u015_FCdisabled
Info Unknown
CHG_u015 - F Cdisabled

Tesla unknown code in the Charger (CHG) module. Fast charging has been disabled.

CHG_w009
CHG_w009_hwFCWeld
Warning Warning
CHG_w009 - HW FC Weld

Tesla warning code in the Charger (CHG) module. The charger's complex programmable logic device (CPLD) has detected an issue with the fast charge contactor fault indicating that the contactors are welded.

CHG_w036
CHG_w036_HVJB_disconnected
Warning Warning
CHG_w036 - HVJB disconnected

Tesla warning code in the Charger (CHG) module. The connection between the master charger and the high voltage junction box (HVJB) logic interface board is disconnected. If this alert is present, there may also be fast charger (FC) contactor welded alerts present whether they are actually welded or not.

CHG_w048
CHG_w048_FCWeldCheckState
Warning Warning
CHG_w048 - FC Weld Check State

Tesla warning code in the Charger (CHG) module. The Fast Charger (FC) contactors are detected by the charger to be in a welded state.

CHG_w062
CHG_w062_FCPosCntrWelded
Warning Warning
CHG_w062 - FC Pos Cntr Welded

Tesla warning code in the Charger (CHG) module. The charger could not determine the state of the fast charge contactors or the fast charge contactors are welded.

CHG_w063
CHG_w063_FCNegCntrWelded
Warning Warning
CHG_w063 - FC Neg Cntr Welded

Tesla warning code in the Charger (CHG) module. The charger could not determine the state of the fast charge contactors or the fast charge contactors may be welded. If this alert is present on vehicles with Gen 1, 2, and 3 chargers, CHG_a063_FCNegCntrWelded should also be set to provide additional alert data.?

CHG_w070
CHG_w070_inputVoltMismatch
Warning Warning
CHG_w070 - input Volt Mismatch

Tesla warning code in the Charger (CHG) module. This alert indicates the voltage sensor in the Gen 3 charger's VI board does not match the voltage sensed by the charger's phase board.

CHG_w083
CHG_w083_allPhasesFaulted
Warning Warning
CHG_w083 - all Phases Faulted

Tesla warning code in the Charger (CHG) module. The alert is set if all phases have used up their retries and are in a faulted state. The cause is most likely exterior to the charger.

CHG_w111
CHG_w111_AttemptToFastCharge
Warning Warning
CHG_w111 - Attempt To Fast Charge

Tesla warning code in the Charger (CHG) module. The vehicle is unable to supercharge or fast charge.

CHG_w116
CHG_w116_HVJBOT
Warning Warning
CHG_w116 - HVJBOT

Tesla warning code in the Charger (CHG) module. The master charger detects an over-temperature condition within the high voltage junction box (HVJB). The temperature sensor is internal to the HVJB and is communicated to the master charger. The temperature reading of the HVJB sensor should be 66�C by default because that is the floor of the sensor value, and it will start logging temperatures above 66�C. This warning is set when temperature is above 70�C.

CHG_w117
CHG_w117_HVJBOTFault
Warning Warning
CHG_w117 - HVJBOT Fault

Tesla warning code in the Charger (CHG) module. The charger has detected an overtemperature event in the high voltage junction box (HVJB).

CHG_w118
CHG_w118_VDiffHwRationality
Warning Warning
CHG_w118 - V Diff HW Rationality

Tesla warning code in the Charger (CHG) module. The Voltage Differential rationality check fails possibly due to a failed isolator between phases or a failed signal line for the voltage differential. This alert can affect the ability to supercharge when aligned with the alert BMS_A096_FC_NO_VOLT_MATCH. This alert does not seem to affect AC charging. It can be present when the contactors are closed or opened.

CHG_w120
CHG_w120_HVJB_powerFault
Warning Warning
CHG_w120 - HVJB power Fault

Tesla warning code in the Charger (CHG) module. The high voltage junction box (HVJB) 12V power supply is below 11.54V.

CHG_w124
CHG_w124_ph3VersionMismatch
Warning Warning
CHG_w124 - ph3Version Mismatch

Tesla warning code in the Charger (CHG) module. There is a version mismatch.

CHG_w125
CHG_w125_leakageTestFailure
Warning Warning
CHG_w125 - leakage Test Failure

Tesla warning code in the Charger (CHG) module. This fault indicates that the voltage decay after the supercharger external isolation test has happened too quickly. During supercharger startup, the supercharger will open the output contactors after performing the external isolation test at 300V. The vehicle then monitors the time it takes for the 300V to decay. If the decay time is sufficient, the start-up sequence proceeds. The purpose of this test is to check the common mode isolation (DC+ to DC-) of the high voltage chain from the supercharger cabinet to the vehicle's fast charge contactors.